NAME
filter - cups file conversion filter interfaces
SYNOPSIS
filter job user title num-copies options [
filter job user title num-copies options [
filename ]
DESCRIPTION
The CUPS filter interface provides a standard
method for adding support for new document types to CUPS. Each
filter is capable of converting from one or more input formats to
another format that can either be printed directly or piped into
another filter to get it to a printable format.
Filters must be capable of reading from a filename on the
command-line or from the standard input, copying the standard input
to a temporary file as required by the file format. All output must
be sent to the standard output.
The command name (argv[0]) is set to the name of the destination
printer.
ENVIRONMENT VARIABLES
The following environment variables
are defined by the CUPS server when executing each filter:
- CHARSET
-
The default text character set (typically us-ascii or iso-8859-1).
- CLASS
-
When a job is submitted to a printer class, contains the name of
the destination printer class. Otherwise this environment variable
will not be set.
- CONTENT_TYPE
-
The MIME type associated with the file (e.g.
application/postscript).
- CUPS_DATADIR
-
The directory where data files can be found.
- CUPS_SERVERROOT
-
The root directory of the server.
- DEVICE_URI
-
The device-uri associated with the printer.
- LANG
-
The default language locale (typically C or en).
- PATH
-
The standard execution path for external programs that may be run
by the filter.
- PPD
-
The full pathname of the PostScript Printer Description (PPD) file
for this printer.
- PRINTER
-
The name of the printer; this is provided for shell scripts which
may not be able to get the passed argv[0] string.
- RIP_CACHE
-
The recommended amount of memory to use for Raster Image Processors
(RIPs).
- SOFTWARE
-
The name and version number of the server (typically CUPS/1.1).
- TZ
-
The timezone of the server.
- USER
-
The user executing the filter, typically lp; consult the cupsd.conf
file for the current setting.
COMPATIBILITY
While the filter interface is compatible with
System V interface scripts, it will only work with the System V
interface script as the only filter. Typically the interface script
will be provided via the
command using the -i option.
SEE ALSO
backend(1),
cupsd(8), CUPS
Interface Design Description, CUPS Software Administrators Manual,
CUPS Software Programmers Manual, http://localhost:631/documentation.html